89/336/EEC
|
|
Council Directive on the Approximation of the Laws of the Member States Relating to electromagnetic Compatibility
|
1998
|
|
|
ANSI T1.311
|
|
American National Standard for Telecommunications—DC Power Systems—Telecommunications Environmental Protectio
|
1998
|
|
|
|
ANSI T1.313
|
|
American National Standard for Telecommunications Electrical Protection for Telecommunications Central Offices and Similar Type Facilities
|
1997
|
|
|
|
ANSIX3.139
|
|
Information Systems—Fiber Distributed Data Interface (FDDI)—Token Ring Media Access Interface (MAC)
|
1987
|
|
|
|
ANSIX3.148
|
|
Information Systems—Fiber Distributed Data Interface (FDDI)—Token Ring Physical Layer Protocol (PHY)
|
1988
|
|
|
|
ANSIX3.166
|
|
Information Systems—Fiber Distributed Data Interface (FDDI)—Physical Layer Medium Dependent (PMD)
|
1989
|
|
|
|
ANSI X3.184
|
|
Information Systems—Fiber Distributed Data Interface (FDDI)—Single mode Fiber Physical Layer medium Dependent (SMF-PMD)
|
1993
|
|
|
|
ANSI X3.229
|
|
Information Systems—Fiber Distributed Data Interface (FDDI)—Station Management (SMT)
|
1994
|
|
|
|
ANSI X3.237
|
|
Information Systems—Fiber Distributed Data Interface (FDDI)—Token Ring Low-Cost Fiber Physical Layer Medium Dependent (LCF-PMD)
|
1995
|
|
|
|
ANSI X3.263
|
|
Information Systems—FDDI—Token Ring Twisted-Pair Physical Layer Medium Dependent (TP-PMD)
|
1995
|
|
|
|
ANSI/ASHRAE135
|
|
BACnet-AData Communication Protocol for Building Automation and Control Network
|
2001
|
|
|
|
ANSI/EI-310-D
|
|
Cabinets,Racks,Panels,andAssociatedEquipment
|
1992
|
|
|
|
ANSI/EIA-709.1-A
|
|
Control Network Protocol Specification
|
1999
|
|
|
|
ANSI/EIA/TIA-455-B
|
|
Standard Test Procedure for Fiber Optic Fibers, Cable, Transducers, Sensors, Connecting and Terminating Devices, and other Fiber Optic Components
|
1998
|
|
|
|
ANSI/ICEAS-80-576
|
|
Category 1 & 2 Individually Unshielded Twisted Pair Indoor Cables for Use in Communications Wiring Systems
|
2000
|
|
|
|
ANSI/ICEA S-83-596
|
|
Fiber Optic Premises Distribution Cable
|
1994
|
|
|
|
ANSI/ICEAS-84-608
|
|
Telecommunications Cable, Filled Polyolefin Insulated Copper Conductor
|
1994
|
|
|
|
ANSI/ICEA S-85-625
|
|
Air core, Polyolefin Insulated, Copper Conductor Telecommunications Cable
|
1996
|
|
|
|
ANSI/ICEA S-87-640
|
|
Fiber Optic Outside Plant Communications Cable
|
1999
|
|
|
|
ANSI/ICEA S-89-648
|
|
Telecommunications Aerial Service Wire
|
1993
|
|
|
|
ANSI/ICEA S-90-661
|
|
Category 3, 5, & 5e Individually Unshielded Twisted Pair Indoor Cable for Use In General Purpose and LAN Communication Wiring Systems
|
2000
|
|
|
|
ANSI/ICEA S-98-688
|
|
Broadband Twisted-Pair Telecommunications Cable Air core, Polyolefin Insulated Copper Conductors
|
1997
|
|
|
|
ANSI/ICEA S-99-689
|
|
Broadband Twisted-Pair Telecommunications Cable Filled Polyolefin Insulated Copper Conductors
|
1997
|
|
|
|
ANSI/IEEE 446
|
|
IEEE Recommended Practice for Emergency and Standby Power Systems for Industrial and Commercial Applications
|
1995
|
|
|
|
ANSI/IEEE 802.3-2000
|
|
Information Technology—Telecommunications and Information Exchange Between systems—Local and Metropolitan Area Networks—Specific Requirements— Part 3: CSMA/CD Access Method and Physical Layer Specifications
|
2000
|
|
|
|
ANSI/IEEE 802,5-1998
|
|
Information Technology—Telecommunications and Information Exchange Between Systems—Local and Metropolitan Area Networks—Specific Requirements—Part 5: Token Ring Access Method and Physical Layer Specifications
|
1998
|
|
|
|
ANSI/IEEE 802.11
|
|
IEEE Standard for Information Technology Telecommunications and Information Exchange Between Systems— Local and Metropolitan Area Networks—Specific Requirements—Part 11: Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications
|
1999 |
|
|
|
ANSI/IEEE 802.12
|
|
IEEE Standard for Information Technology— Telecommunications and Information Exchange Between Systems —Local and Metropolitan Area Networks—Specific Requirements—Part 12: Demand- Priority Access Method, Physical Layer and Repeater Specifications for 100 Mb/s Operation
|
1998 |
|
|
|
ANSI/IEEE1100
|
|
Recommended Practice for Powering and Grounding Sensitive Electronic Equipment in Industrial and Commercial Power Systems
|
1999 |
|
|
|
ANSI/IEEE 1394 |
|
IEEE Standard for a High Performance Serial Bus FireWire™
|
1995 |
|
|
|
ANSI/NECA/BICSI-568 |
|
Standard for Installing Commercial Building Telecommunications Cabling
|
January 2002
|
|
|
|
ANSI/TIA/EIA-222-F |
|
Structural Standards for Steel Antenna Towers and Antenna Supporting Structures
|
June 1996
|
|
|
|
ANSI/TIA/EIA-232-F |
|
Interface Between Data Terminal Equipment and Data Circuit-Terminating Equipment Employing Serial Binary Data Interchange
|
1997
|
|
|
|
ANSI/TIA/EIA-422-B |
|
Electrical Characteristics of Balanced Voltage Digital Interface Circuits
|
1994 |
|
|
|
ANSI/TIA/EIA-455-61 |
|
FOTP61. Measurement of Fiber or Cable Attenuation
|
2000 |
|
|
|
ANSI/TIA/EIA-455-171 |
|
FOTP171. Attenuation by Substitution Measurement for Short Length Multimode and Graded Index and Single mode Optical Fiber Cable Assemblies
|
2001 |
|
|
|
ANSI/TIA/EIA-485-A |
|
Electrical Characteristics of Generators and Receivers for Use in Balanced Digital Multipoint Systems
|
March 1998
|
|
|
|
ANSI/TIA/EIA-492-AAAA-A |
|
DetailSpecificationfor62.5umCoreDiameter/125umCladding Diameter Class la Graded Index Multimode Optical Fibers
|
January 1998
|
|
|
|
ANSI/TIA/EIA-492- AAAB |
|
DetailSpecificationfor50 umCoreDiameter/125umCladding Diameter Class la Graded Index Multimode Optical Fibers
|
November 1998
|
|
|
|
AN S I/TIA/E IA-492-CAAA |
|
Detail Specification for Class IVa Dispersion—Unshifted Single-Mode Optical Fibers
|
May 1998
|
|
|
|
ANSI/TIA/EIA-526 |
|
Standard Test Procedures for Fiber Optic Systems
|
September 1992
|
|
|
|
ANSI/TIA/EIA-526-7 |
|
OFSTP 7. Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant
|
July 1998 |
|
|
|
ANSI/TIA/EIA-526-14A |
|
OFSTP14A. Optical Power Loss Measurements of Installed Muff/mode Fiber Cable Plant
|
August 1998 |
|
|
|
ANSI/TIA/EIA-568-B.1 |
|
Commercial Building Telecommunications Cabling Standard Part 1: General requirements
|
April 2001 |
|
|
|
ANSI/TIA/EIA-568-B.1-1 |
|
CommercialBuildingTelecommunicationsabling Standard Part 1: General Requirements—Addendum 1 —Minimum 4-Pair UTP and 4-Pair ScTP Patch Cable
Bend Radius
|
August 2001 |
|
|
|
ANSI/TIA/EIA-568-B.2 |
|
Commercial Building Telecommunications Cabling Standard Part 2: Balanced Twisted-Pay Cabling Components
|
April
2001 |
|
|
|
ANSI/TIA/EIA-568-B.3 |
|
Optical Fiber Cabling Components Standard
|
April
2000 |
|
|
|
ANSI/TIA/EIA-569-A |
|
Commercial Building Standard for Telecommunications Pathways and Spaces
|
February
1998 |
|
|
|
ANSI/TIA/EIA-569-A-1 |
|
Commercial Building Standard for Telecommunications Pathways and Spaces, Addendum 1—Surface Raceways
|
April
2000 |
|
|
|
ANSI/TIA/EIA-569-A-2 |
|
Commercial Building Standard for Telecommunications Pathways and Spaces, Addendum 2—Furniture Pathways and Spaces
|
April
2000 |
|
|
|
ANSI/TIA/EIA-569-A-3 |
|
Commercial Building Standard for Telecommunications Pathways and Spaces, Addendum 3—Access Floors
|
March
2000 |
|
|
|
ANSI/TIA/EIA-569-A-4 |
|
Commercial Building Standard for Telecommunications Pathways and Spaces, Addendum 4—Poke-Thru Fittings
|
April 2000
|
|
|
|
ANSI/TIA/EIA-569-A-5 |
|
Commercial Building Standard for Telecommunications Pathways and Spaces, Addendum 5—In Floor Systems
|
June 2001
|
|
|
|
ANSI/TIA/EIA-569-A-6 |
|
Commercial Building Standard for Telecommunications Pathways and Spaces, Addendum 6—Multi-Tenant Pathways and Spaces
|
September
2001 |
|
|
|
ANSI/TIA/EIA-570-A |
|
Residential Telecommunications Cabling Standard
|
October
1999 |
|
|
|
ANSI/TIA/EIA-571-A |
|
Telecommunications User Premises Equipment Environmental Considerations
|
1999 |
|
|
|
ANSI/TIA/EIA-598-A |
|
Optical Fiber Cable Color Coding
|
May
1995 |
|
|
|
ANSI/TIA/EIA-604-2 |
|
FOCIS 2—Fiber Optic Connector IntermafeabilHy Standard
|
November
1997 |
|
|
|
ANSI/TIA/EIA-604-3 |
|
FOCIS 3—Fiber Optic Connector Intermateabilify Standard
|
August
1997 |
|
|
|
ANSI/TIA/EIA-604-4-A |
|
Fiber Optic Connector Intermateability Standard , Type FC and FC-APC
|
October 2000 |
|
|
|
ANSI/TIA/EIA-604-5-A |
|
FOCIS 5—Fiber Optic Connector Intermateability Standard, Type MPO
|
September
2001 |
|
|
|
ANSI/TIA/EIA-604-6 |
|
FOCIS 6—Fiber Optic Connector Intermateability Standard (Fiber Jack Connector)
|
March
1999 |
|
|
|
ANSI/TIA/EIA-604-7 |
|
FOCIS 7—Fiber Optic Connector Intermateability Standard
|
January
1999 |
|
|
|
ANSI/TIA/EIA-604-10 |
|
FOCIS 10—Fiber Optic Connector Intermateabilify Standard
|
October 1999 |
|
|
|
ANSI/TIA/EIA-604-12 |
|
FOCIS 12—Fiber Optic Intermateability Standard, Type MT-RJ
|
September 2000 |
|
|
|
ANSI/TIA/EIA-606-A |
|
Administration Standard for Commercial Telecommunications Infrastructure
|
2002 |
|
|
|
ANSI/TIA/EIA-607 |
|
Commercial Building Grounding and Bonding Requirements for Telecommunications
|
August 1994 |
|
|
|
ANSI/TIA/EIA-631 |
|
Telecommunications Telephone Terminal Equipment— Radio Frequency Immunity Requirements for Equipment Having an Acoustic Output
|
April 1996 |
|
|
|
ANSI/TIA/EIA-758 |
|
Customer-Owned Outside Plant Telecommunications Cabling Standard
|
April 1999 |
|
|
|
ANSI/TIA/EIA-758-1 |
|
Addendum No. 1 to TIA/EIA-758 Customer-Owned Outside Plant Telecommunications Cabling Standard
|
April 1999 |
|
|
|
ANSI/TIA/EIA-854 |
|
A Full Duplex Ethernet Specification for 1000 Mb/s (1000BASE-TX) Operating Over Category 6 Balanced Twisted-Pair Cabling
|
June 2001 |
|
|
|
AS 3084 |
|
Telecommunications Installations—Telecommunications Pathways and Spaces for
Commercial Buildings
|
1993 |
|
|
|
AS/ACIF 009 |
|
Installation Requirements for Customer Cabling (Wiring Rules)
|
2001 |
|
|
|
AS/NZS3080 |
|
Telecommunications Installations—Integrated Telecommunication Cabling System premises
|
2000 |
|
|
|
AS/NZS3085.1 |
|
Telecommunications Installations—Administration of Communications Cabling Systems—Basic Requirements
|
1995 |
|
|
|
AS/NZS3086 |
|
Telecommunications Installations—Integrated Telecommunications for Small Office-
/Home Office Premises
|
1996 |
|
|
|
ASTMB258-01 |
|
Standard Specification for Standard Nominal Diameters andCross-Section area AWG Sizes of Round Wires Used as Electrical Conductor
|
2001 |
|
|
|
ASTM D4566 |
|
Standard Test Methods for Electrical Performance properties of Insulations and Jackets for Telecommunications Wire and Cabl
|
1998 |
|
|
|
ASTME119-98 |
|
Standard Test Method for Fire Tests of Through Penetration Fire Stops
|
2000 |
|
|
|
ASTME814-00 |
|
Standard Test Method for Fire Tests of Through Penetration Fire Stops
|
2000 |
|
|
|
BOCA |
|
The BOCA National Building Code
|
January 1994
|
|
|
|
BS7718 |
|
Installation of Fibre Optic Cabling (Code of Practice)
|
September 1996 |
|
|
|
CAN/CSA-T525 |
|
Residential Wiring for Telecommunications
|
1999 |
|
|
|
CAN/CSA-T527 |
|
Grounding and Bonding for Telecommunications in Commercial Buildings
|
1999 |
|
|
|
CAN/CSA-T528 |
|
DesignGuidelinesforAdministration of Telecommunications Infrastructure in Commercial
Buildings
|
1997 |
|
|
|
CAN/CSA-T529 |
|
Telecommunications Cabling Systems in Commercial Buildings (Adopted ANSI/TIA/EIA-568-Awith modifications )
|
1995 |
|
|
|
CAN/CSA-T530 |
|
Commercial Building Standard for Telecommunications Pathways and Spaces (Adopted ANSI/TIA/EIA-569-A)
|
1999 |
|
|
|
CAN/ULC(ISSN0319-2318) |
|
List of Equipment and Materials. Fire Resistance Ratings
|
1995 |
|
|
|
CAN/ULC-S101 |
|
Fire Endurance Tests of Building Construction and Materials
|
1989 |
|
|
|
CAN/ULC-S102.4-M |
|
Test for Fire and Smoke Characteristics of Electrical Wiring and Cable
|
1987 |
|
|
|
CAN/ULC-S115 |
|
Fire Tests of Fire stop Systems
|
1995 |
|
|
|
CENELEC EN 50081-1 |
|
Electromagnetic Compatibility—Generic Emission Standard—1:Residential,Commercial, and Light Industrial
|
1992 |
|
|
|
CENELECEN50081-2 |
|
Electromagnetic Compatibility—Generic Emission Standard—Part 2: Industrial Environment
|
1993 |
|
|
|
CENELEC EN 50082-1 |
|
Electromagnetic Compatibility—Generic Immunity 1:Residential,Commercial,and Light Industrial
|
1997 |
|
|
|
CENELECEN50082-2 |
|
Electromagnetic Compatibility—Generic Immunity Standard-part2:Industrial Environment
|
1995 |
|
|
|
CENELECEN50173 |
|
Information Technology—Generic Cabling Systems
|
November 1996
|
|
|
|
CENELEC EN 50174-1 |
|
Information Technology—Cabling Installation—Part1: QualityAssurance;GermanVersion
EN 50174:2000
|
2000 |
|
|
|
CENELEC EN 50174-2 |
|
Information Technology—Cabling Installation—Part 2: Installation Planning and Practices Inside Buildings
|
2000 |
|
|
|
CENELECEN50310 |
|
Application of Equipotent Bonding and Earthling in Buildings with Information Technology Equipment
|
2000 |
|
|
|
CENELECEN 50346 |
|
Information Technology—Cabling Installation—Testing of installed cable
|
Draft |
|
|
|
CENELECEN 55022 |
|
Limits and Methods of Measurement of Radio Interference Characteristics of IT
Equipment
|
September
1998 |
|
|
|
CENELECEN 55024 |
|
InformationTechnologyEquipment—Immunity Characteristics—Limits and Methods of Measurement
|
1998 |
|
|
|
CENELECEN60794-1-1 |
|
Optical Fibre Cables Part 1-1: Generic Specification -General
|
December
2001 |
|
|
|
CENELEC EN 61000-3-2 |
|
Electromagnetic Compatibility (EMC)—Limits for Harmonic Current Emissions (Equipment Input Current Up to and Including 15 A per Phase)
|
1995 |
|
|
|
CENELEC EN 61000-3-3 |
|
Electromagnetic Compatibility(EMC)—Limitation of Voltage Fluctuations and Flicker in Low-Voltage Supply Systems for Equipment with Rated Current Up to 16A
|
1995 |
|
|
|
CENELEC EN 61000-4-1 |
|
Electromagnetic Compatibility (EMC)—Overview of Immunity Tests—Basic EMC Publication
|
1995 |
|
|
|
CENELEC EN 61000-4-2 |
|
Electromagnetic Compatibility(EMC)—Electrostatic Discharge Immunity Test—Basic EMC Publication
|
1995 |
|
|
|
CENELEC EN 61000-4-3 |
|
Electromagnetic Compatibility (EMC)—Radiated Radio-Frequency Electromagnetic Field Immunity Test
|
1995 |
|
|
|
CENELEC EN 61000-4-4 |
|
Electromagnetic Compatibility (EMC)—Electrical Fast Transient/Burst Immunity Test—Basic EMC Publication
|
1995 |
|
|
|
CENELEC EN 61000-4-6 |
|
Electromagnetic Compatibility (EMC)—Immunity to Conducted Disturbances Induced by Radio-Frequency Fields
|
1996 |
|
|
|
CENELEC EN 61000-6-2 |
|
ElectromagneticCompatibility(EMC)—Generic Standards—Immunity for Industrial Environment
|
1999 |
|
|
|
CSA-C22.1 |
|
Canadian Electrical Code®, Part 1
|
2002 |
|
|
|
CSA-C22.1HB |
|
Canadian Electrical Code® Handbook
|
2002 |
|
|
|
EIA195-C |
|
Electrical and Mechanical Characteristics for Terrestrial Microwave Relay and System Antennas and Passive Reflections
|
1987 |
|
|
|
EIA600 |
|
CEBus Industry Council. Home Automation System
|
1992 |
|
|
|
EIA TSB110 |
|
Residential Gateway
|
December 1999 |
|
|
|
FCC |
|
Code of Federal Regulations, Title 47, Telecommunications, Part 22, Public Mobile Services
|
October 1998 |
|
|
|
FCC |
|
Code of Federal Regulations, Title 47, Telecommunications Parts 40-69
|
October
1998 |
|
|
|
FCC |
|
Code of Federal Regulations, Title 47, Telecommunications, Part 68, Connection of Terminal Equipment to the Telephone Network
|
October 1998 |
|
|
|
FCC |
|
Code of Federal Regulations, Title 47, Telecommunications, Part 76, Cable Television Service
|
October 1998 |
|
|
|
FCC |
|
Code of Federal Regulation , Title 47,Part 76.605 ,Technical Standards
|
October 1998 |
|
|
|
FIPS PUB 94 |
|
Guideline on Electrical Power for ADP Installations
|
1997 |
|
|
|
ICBO |
|
Uniform B1996uilding Code
|
1997 |
|
|
|
IEC 60603-7 |
|
Connectors for Frequencies Below 3 MHz for Use with Printed Boards—Part 7: Detail Specification for Connectors, 8-Way, Including Fixed and Free Connectors with Common Mating Features, with Assessed Quality
|
1996 |
|
|
|
I EC 60874-10 |
|
Connectors for Optical Fibres and Cables—Part 10: Sectional Specification Fibre Optic Connector—Type BFOC/2.5
|
1992 |
|
|
|
I EC 60874-14 |
|
Connectors for Optical Fibres and Cables—Part 14: Sectional Specification for Fibre Optic Connector-Type SC
|
1993 |
|
|
|
IEC 60874-19 |
|
Connectors for Optical Fibres and Cables—Part 19: Sectional Specification for Fibre Optic Connector—Type SC-D[uplex]
|
1995 |
|
|
|
IEC 60874-19-1 |
|
Connectors for Optical Fibers and Cables—Part 19-1: Fibre Optic Patch Cord connector SC-PC (floating duplex) Standard Terminated on Multimode Fiber Type A1a, A1b—Detail Specification (work in progress)
|
1999 |
|
|
|
IEC 61000-3-2 |
|
Electromagnetic Compatibility (EMC)—Part 3-2: Limits for Harmonic Current Emissions (Equipment Input Up to and Including 16A per Phase)
|
2001 |
|
|
|
IEC 61000-3-3 |
|
Electromagnetic Compatibility (EMC)—Part 3-3: Limits —Limitation of Voltage Changes, Voltage Fluctuations and Flicker in Public Low-Voltage Supply Systems for
Equipment with Rated Current up to 16A per Phase
|
1994 |
|
|
|
IEC 61000-4-8 |
|
Electromagnetic Compatibility (EMC)—Part 4-8: Testing and Measurement Techniques—Power Frequency Magnetic Field Immunity Test
|
2001 |
|
|
|
IEC 61000-4-11 |
|
Electromagnetic Compatibility (EMC)—Part 4-11 Testing and Measurement Techniques—Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests
|
2001 |
|
|
|
IEC 61000-6-1 |
|
Electromagnetic Compatibility (EMC)—Part 6: Generic Standards—Section 1: Immunity for Residential, Commercial, and Light Industrial Environments
|
1997 |
|
|
|
IEC 61000-6-4 |
|
Electromagnetic Compatibility (EMC)—Part 6: Generic Standards—Section 4: Emission Standard for Industrial Environments
|
1997 |
|
|
|
IEC CISPR-22 |
|
Information Technology Equipment—Radio Disturbance Characteristics—Limits and Methods of Measurement
|
1997 |
|
|
|
IEC CISPR-24 |
|
Information Technology Equipment—Immunity Characteristics—Limits and Methods of Measurement
|
1997 |
|
|
|
IEEE 81 |
|
IEEE Guide for Measuring Earth Resistively, Ground Impedance, and Earth Surface Potentials of a Ground System (Part 1: Normal Measurements)
|
1983 |
|
|
|
IEEE 81.2 |
|
IEEE Guide for Measurement of Impedance and Safety Characteristics of Large, Extended or Interconnected Grounding Systems (Part 2)
|
1991 |
|
|
|
IEEE 142 |
|
IEEE Recommended Practice for Grounding of Industrial and Commercial Power System
|
1991 |
|
|
|
IEEE 241 |
|
IEEE Recommended Practice for Electrical Systems in Commercial Buildings
|
2000 |
|
|
|
IEEE 446 |
|
IEEE Recommended Practice for Emergency and Standby Power Systems for Industrial and Commercial Applications
|
1995 |
|
|
|
IEEE 450 |
|
IEEE Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications
|
1995 |
|
|
|
IEEE 518 |
|
IEEE Guide for the Installation of Electrical Equipment to Minimize Electrical Noise Inputs to Controllers from External Sources
|
1982 |
|
|
|
IEEE 519 |
|
IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems
|
1992 |
|
|
|
IEEE 802.3a |
|
Section 10, Medium Attachment Unit and Baseband Medium Specification, Type 10BASE-2
|
1988 |
|
|
|
IEEE 802.3ab |
|
IEEE Standard for Information Technology –Telecommunication and Information Exchange Between System –Local and Metropolitans Area Network –Part3:CSMA/CD Access Method and Physical Layer Specification –Physical Layer Parameters and Specifications for 1000 Mb/s Operation Over 4 Pairs of Category 5 Balanced Copper Cabling , Type 1000 Base-T
|
1999 |
|
|
|
IEEE 802.3ac |
|
IEEE Standard for Information Technology— Telecommunications and Information Exchange Between Systems—Local and Metropolitan Area Networks—Common Specifications—Specific Requirements—Part 3: CSMA/CD Frame Extensions for VLAN Tagging
|
1998 |
|
|
|
IEEE 802.3ae |
|
IEEE Standard for Information Technology—Local Metropolitan Area Networks—Part 3: CSMA/CD Access Method and Physical Layer Specifications— Media access Control Parameters, Physical Layers and Management Parameters for 10 Gb/s Operation
|
draft |
|
|
|
IEEE 802.3b |
|
Supplement to 802.3—Broadband Medium Attachment Unit and Broadband Medium Specifications, Type 10BROAD-36 (Section 11)
|
1985 |
|
|
|
IEEE 802.3c |
|
Supplement to 802.3—Repeater Unit for 10 Mb/s Base band Networks (Sections 9.1-9.8)
|
1985 |
|
|
|
IEEE 81.3i |
|
Supplement to 802.3—System Considerations for Multisegment 10 Mb/s Base band Networks (Section 13) and Twisted-Pair Medium Attachment Unit and Base band Medium Specification, Type 10BASE-T (Section 14)
|
1990 |
|
|
|
IEEE 81.3j |
|
Supplement to 802.3—Fiber Optic Active and PassiveStar-Based Segments, Type 10BASE-F (Sections 15-18)
|
1993 |
|
|
|
IEEE 81.3t |
|
Informative Annex for Support of 120-Ohm Cables in10BASE-T Simplex Link Segment
|
1995 |
|
|
|
IEEE 801.3u |
|
Local and Metropolitan Area Networks—Supplement Media/Access Control(MAC) Parameters, Physical Layer, Medium Attachment Units, and Repeater for 100 Mb/s Operation, Type 100BASE-T (Classes 21-30)
|
1995 |
|
|
|
IEEE 801.3v |
|
Supplement to 802.3—Informative Annex for Support of 150-Ohm Cables in 10BASE-T Link Segment
|
1995 |
|
|
|
IEEE 801.3y |
|
IEEE Standards for Local and Metropolitan Area Networks: Physical Layer Specification for 100 Mb/s Operation on Two Pairs of Category 3 or Better Balanced Twisted-pair Cable (100BASE-T2)
|
1997 |
|
|
|
IEEE 801.3z |
|
Media Access Control Parameters, Physical Layers, Repeater and Management prameters for 1,000 Mb/s Operation, Supplement to Information Technology— Local and Metropolitan Area Networks—Part 3: CSMA/CD /Access Method and Physical Layer
Specifications
|
1998 |
|
|
|
IEEE 801.5j |
|
Token Ring Access Method and Physical Layer Specifications—Fiber Optic Media Station Attachment
|
1993 |
|
|
|
IEEE 801.5r |
|
Token Ring Access Method and Physical Layer Specifications—Dedicated Token Ring Operation
|
1997 |
|
|
|
IEEE 801.5t |
|
Token Ring Access Method and Physical Layer Specifications—100 Mb/s Dedicated Token Ring Operation
|
2000 |
|
|
|
IEEE 802.5v |
|
Token Ring Access Method and Physical Layer Specifications—Gigabit Token Ring operation
|
2001 |
|
|
|
IEEE 802.7 |
|
IEEE Recommended Practices for Broadband Local Area Networks
|
1998 |
|
|
|
IEEE 802.9 |
|
Information Technology-Telecommunication and Information Exchenge Between Systems-Local and Metropolitan Area Networks-Specific Requirements-Part9:Integrated Service (IS)
LAN Interface at the Medium Access Control (MAC)
|
1996 |
|
|
|
IEEE 802.10 |
|
Local and Metropolitan Area Networks: Interoperable LAN/MAN Security (SILS)
|
1998 |
|
|
|
IEEE 802.11 |
|
IEEE Standard for Information Technology—Telecommunications and Information Exchange Between Systems—Local and Metropolitan Area Networks—Specific Requirements—Part 11: Wireless LAN MAC and Physical Layer Specifications
|
1997 |
|
|
|
IEEE 802.11a |
|
IEEE Standard for Information Technology—Telecommunications and Information Exchange Between Systems—Local and Metropolitan Area Networks—Specific requirements—Part11:Wireless MAC and Physical Layer Specifications: High Speed
Physical Layer in the 5 GHz Band
|
1999 |
|
|
|
IEEE802.11b |
|
IEEE Standard for Information Technology-Telecommunications and Information Exchange
Between Systems—Local and Metropolitan Area Networks—Specific Requirements—Part 11: Wireless LAN MAC and Physical Layer Specifications: Higher Speed Physical Layer Extension in the 2.4 GHz Band
|
1999 |
|
|
|
IEEE802.12 |
|
IEEE Standards for Local and Metropolitan Networks: Demand Priority /Access Method, Physical Layer and Repeater Specifications
|
1995 |
|
|
|
IEEE802.15 |
|
Standard for Telecommunications and Information Exchange Between Systems—LAN/MAN—Specific Requirements—Part 15: Wireless MAC and Physical Layer specifications for Wireless Personal Area Networks
|
draft |
|
|
|
IEEE802.3ad |
|
IEEE Standard for Information Technology—Local and Metropolitan Area Networks—Part 3: CSMA/CD Access Method and Physical Layer Specifications—Aggregation of Multiple Link Segments
|
2000 |
|
|
|
IEEE1100 |
|
Powering and Grounding Sensitive Electronic Equipment
|
1999 |
|
|
|
IEEE1184 |
|
IEEE Guide for the Selection and Sizing of Batteries for Uninterruptible Power Systems
|
1994 |
|
|
|
IEEE 1187 |
|
IEEE Recommended Practice for Installation Design and Installation of Valve-Regulated Lead-Acid (VRLA) Storage Batteries for Stationary Applications
|
1996 |
|
|
|
IEEE 1188 |
|
IEEE Recommended Practice for Maintenance, Testing, and Replacement of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary Applications
|
1996 |
|
|
|
IEEE 1189 |
|
IEEE Guide for Selection of Valve-Regulated Lead-Acid (VRLA) Storage Batteries for Stationary Applications
|
1996 |
|
|
|
IEEE C2 |
|
National Electrical Safety Code®, 2002 edition
|
2001 |
|
|
|
IEEE C62.1 |
|
IEEE Standard for Gapped Silicon-Carbide Surge Arresters for AC Power Circuits
|
1989 |
|
|
|
IEEE C62.41 |
|
IEEE Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits
|
1991 |
|
|
|
IEEE C62.45 |
|
IEEE Guide on Surge Testing for Equipment Connected to Low-Voltage AC Power Circuits
|
1992 |
|
|
|
ISO/IEC 8802-2 |
|
Information Technology—Telecommunications and Information Exchange Between Systems—Local Area Networks—Specific Requirements—Part 2: Logical Link Control
|
1998 |
|
|
|
ISO/IEC 8802-3 |
|
Information Technology—Telecommunications and Information Exchange Between Systems—Part 3: Carrier Sense Multiple Access with Collision Detection (CSMA/CD) Access Method and Physical Layer Specifications
|
2000 |
|
|
|
ISO/IEC 8802-5 |
|
Information Technology—Telecommunications and Information Exchange Between Systems—Local and Metropolitan Area Networks—Specific Requirements—Part 5: Token Ring Access Method and Physical Layer Specifications
|
1998 |
|
|
|
ISO/IEC 8877 |
|
Information Technology—Telecommunications and Information Exchange Between Systems—Interface Connector and Contact Assignments for ISDN Basic Access Interface Located at Reference Points S and T
|
1992 |
|
|
|
ISO/IEC 11172-1 |
|
Information Technology—Coding of Moving Pictures and Associated Audio for Digital Storage Media at up to about 1.5 Mbits—Part 1: Systems
|
1993 |
|
|
|
ISO/IEC 11172-2 |
|
Information Technology—Coding of Moving Pictures and Associated Audio for Digital Storage Media at up to about 1.5 Mbits—Part 2: Video
|
1993 |
|
|
|
ISO/IEC 11172-3 |
|
Information Technology—Coding of Moving Pictures and Associated Audio for Digital Storage Media at up to about 1.5 Mbits—Part 3: Audio
|
1993 |
|
|
|
ISO/IEC 11172-4 |
|
Information Technology—Coding of Moving Pictures and Associated Audio for Digital Storage Media at up to about 1.5 Mbits—Part 4: Compliance Testing
|
1995 |
|
|
|
ISO/IEC 11172-5 |
|
Information Technology—Coding of Moving Pictures and Associated Audio for Digital Storage Media at up to about 1.5 Mbits—Part 5: Software Simulation
|
1998 |
|
|
|
ISO/IEC 11801 |
|
Information Technology—Generic Cabling for Customer Premises
|
2000 |
|
|
|
ISO/IEC 13818-1 |
|
Information Technology—Generic Coding of Moving Pictures and Associated Audio Information—Part 1:Systems
|
2000 |
|
|
|
ISO/IEC 13818-2 |
|
Information Technology—Generic Coding of Moving Pictures and Associated Audio Information—Part 2:Video
|
2000 |
|
|
|
ISO/IEC 13818-3 |
|
Information Technology—Generic Coding of Moving Pictures and Associated Audio Information—Part 3:Audio
|
1998 |
|
|
|
ISO/IEC 13818-4 |
|
Information Technology—Generic Coding of Moving Pictures and Associated Audio Information—Part 4:Conformance Testing
|
1998 |
|
|
|
ISO/IEC 13818-5 |
|
Information Technology—Telecommunications and Information Exchange Between Systems—Local and Metropolitan Area Networks—Specific Requirements—Part 5: Token Ring Access Method and Physical Layer Specifications
|
1998 |
|
|
|
ISO/IEC 13818-6 |
|
Information Technology—Generic Coding of Moving Pictures and Associated Audio Information—Part 6:Extensions for DSM-CC
|
1998 |
|
|
|
ISO/IEC 13818-7 |
|
Information Technology—Generic Coding of Moving Pictures and Associated Audio Information—Part 7:Advanced Audio Coding (AAC)
|
1997 |
|
|
|
ISO/IEC 13818-9 |
|
Information Technology—Generic Coding of Moving Pictures and Associated Audio Information—Part 9; Extension for Real Time Interface for System Decoders
|
1996 |
|
|
|
ISO/IEC 14496-1 |
|
Information Technology—Coding of Audio-Visual Objects—Part 2: Visual
|
2001 |
|
|
|
ISO/IEC 14496-2 |
|
Information Technology—Coding of Audio-Visual Objects—Part 3: Audio
|
1999 |
|
|
|
ISO/IEC 14496-3 |
|
Information Technology—Coding of Audio-Visual Objects—Part 3: Audio
|
1999 |
|
|
|
ISO/IEC 14496-4 |
|
Information Technology—Coding of Audio-Visual Objects—Part 4: Conformance Testing
|
2001 |
|
|
|
ISO/IEC 14496-5 |
|
Information Technology—Coding of Audio-Visual Objects—Part 5: Reference Software
|
2001 |
|
|
|
ISO/IEC 14496-6 |
|
Information Technology—Coding of Audio-Visual Objects—Part 6; Delivery Multimedia Integration Framework (DMIF)
|
2001 |
|
|
|
ISO/IEC 14763-1 |
|
Information Technology—Implementation and Operation of Customer Premises Cabling—Part 1:Administration
|
1999 |
|
|
|
ISO/IEC TR 11802-4 |
|
Part 4: Token Ring Access Method and Physical Layer Specifications—Fibre Optic Station Attachment
|
1996 |
|
|
|
ITU-T.H.261 |
|
Video Codes for Audiovisual Services at PX64 KBIT/S
|
1993 |
|
|
|
ITU-T.H.320 |
|
Narrow-Band Visual Telephone Systems and Terminal Equipment—Series H: Audiovisual and Multimedia Systems Infrastructure of Audiovisual Services
|
1999 |
|
|
|
ITU-T.H.323 |
|
Packet-Based Multimedia Communications Systems— Series H: Audiovisual and ultimedia Systems—Infrastructure of Republished Audiovisual Services
|
2000 |
|
|
|
ITU-T.H.324 |
|
Terminal for Low Bit-Rate Multimedia Communications —Series H: Audiovisual and Multimedia Systems—Infrastructure of Audiovisual Services Systems and Terminal equipment for Audiovisual Service Study Group 16
|
1998 |
|
|
|
ITU-T.T.120 |
|
Data Protocols for Multimedia Conferences—Series T:Terminal Equipment and Protocols forTelematic Services Study Group 8
|
1996 |
|
|
|
NEMAWC63.1 |
|
Performance Standard for Twisted-Pair Premise Voice and Data Communications Cable
|
2000 |
|
|
|
NEMAWC63.2 |
|
Performance Standard for Coaxial Premise Data Communications Cable
|
1996 |
|
|
|
NEMAWC66 |
|
Performance Standard for Category 6 and Category 7 100 Ohm Shielded and Unshielded Twisted-pair Cables National Electrical Code® Handbook
|
2001 |
|
|
|
NFPA |
|
National Electrical Code
|
2002 |
|
|
|
NFPA70 |
|
Information Technology—Implementation and Operation of Customer Premises Cabling—Part 1:Administration
|
2002 |
|
|
|
NFPA70E |
|
Standard for Electrical Safety Requirements for Employee Workplaces
|
2000 |
|
|
|
NFPA72 |
|
National Fire Alarm Code'"
|
1999 |
|
|
|
NFPA75 |
|
Standard for the Protection of Electronic Computer/ Data Processing Equipment
|
1999 |
|
|
|
NFPA101 |
|
Life Safety*3 Code
|
2000 |
|
|
|
NFPA251 |
|
Standard Methods of Tests of Fire Endurance of Building Construction and Materials
|
1999 |
|
|
|
NFPA255 |
|
Standard Method of Test of Surface Burning Characteristics of Building Materials
|
2000 |
|
|
|
NFPA262 |
|
Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-Handling Spaces
|
1999 |
|
|
|
NFPA780 |
|
Standard for the Installation of Lightning Protection Systems
|
2000 |
|
|
|
NFPA1221 |
|
Standard for the Installation, Maintenance, and Use of Public Fire Service Communications Systems National Building Code of Canada
|
1999 |
|
|
|
NRCC 38726 |
|
National Building Code of Canada
|
1995 |
|
|
|
NRCC 38727 |
|
National Fire Code of Canada
|
1995 |
|
|
|
OSHA |
|
Jobsite Safety Handbook
|
1999 |
|
|
|
OSHA |
|
Occupational Safety and Health Act of 1970. Title 29
|
1970 |
|
|
|
OSHA 30071 |
|
General Industry Standards "
|
1998 |
|
|
|
OSHA Regulations
(Standards-29 CFR)—
1910 |
|
General Industry Standards
|
2001 |
|
|
|
OSHA Regulations
(Standards-29 CFR)—
1910 |
|
Permit-Required Confined Spaces
|
1998 |
|
|
|
OSHA Regulations
(Standards-29 CFR)—
1926 |
|
Construction Standards
|
2001 |
|
|
|
SBBCI |
|
The Standard Building Code
|
1999 |
|
|
|
SCTE-IPS-SP-001 |
|
Flexible R.F. Coaxial Drop Cable
|
June 1999 |
|
|
|
SCTE-IPS-SP-100 |
|
Specification for Trunk, Feeder, and Distribution CoaxCable
|
January 1997 |
|
|
|
SCTE-IPS-SP-401 |
|
"F" Port (Male Feed Thru) Physical Dimensions
|
October 1999 |
|
|
|
SCTE-IPS-SP-404 |
|
"F" Connector (Male Indoor) Installation and Performance
|
October 1997 |
|
|
|
TIA/EIA-475EOOO |
|
Sectional Specification for Fiber Optic Connectors—TypeBFOC/2.5
|
1992 |
|
|
|
TIA/EIA-785 |
|
100 Mb/s Physical Layer Medium Dependent Sub layer and 10 Mb/s and 100 Mb/s Auto-Negotiation on 850 nm Fiber Optics
|
May 2001 |
|
|
|
TIA/EIA-729 |
|
Technical Specifications for 100-Ohm Screened Twisted-Pair Cabling
|
August
1999 |
|
|
|
U.S. Coast and Geodetic
Survey |
|
Special Publication No. 8—Formulas and Tables for the Computation of Geodetic Position
Americans with Disabilities Act of 1990
|
1990 |
|
|
|
U.S. Public Law 336 |
|
Americans with Disabilities Act of 1990
|
Published annually |
|
|
|
Ul |
|
Fire Resistance Directory
|
|
|
|
|
Ul 263 |
|
Fire Test of Building Construction and Materials
|
1997 |
|
|
|
Ul 444 |
|
Communication
|
2002 |
|
|
|
Ul 497 |
|
Protectors for Paired Conductor Communications Circuits
|
2001 |
|
|
|
UL 497A |
|
Secondary Protectors for Communications Circuits
|
2001 |
|
|
|
UL 497B |
|
Protectors for Data Communications and Fire Alarm Circuits
|
1999 |
|
|
|
Ul514A |
|
Metallic Outlet Boxes
|
1996 |
|
|
|
Ul910 |
|
Test Method for Fire and Smoke Characteristics of lectrical and Optical-Fiber Cables Used in Air-Handling Spaces
|
1994 |
|
|
|
UL1449-2 |
|
Transient Voltage Surge Suppressors
|
1996 |
|
|
|
UL 1459 |
|
Underwriters Laboratories Standard for Safety—Telephone Equipment
|
1999 |
|
|
|
UL 1479 |
|
Fire Tests of Through-Penetration Firestops
|
1998 |
|
|
|
UL 1685 |
|
Vertical-Tray Fire-Protection and Smoke Release Test for Electrical and Optical-Fiber Cables
|
1997 |
|
|
|
UL 1863 |
|
Communication Circuit Accessories
|
2000 |
|
|
|
UL 1887 |
|
Fire Test of Plastic Sprinkler Pipe for Flame and Smoke Characteristics
|
1996 |
|
|
|
Ul 2043 |
|
Fire Test for Heat and Visible Smoke Release for Discrete Products and their Accessories Installed in Air-Handling Spaces
|
1996 |
|
|
|
Ul 2079 |
|
Test for Fire Resistance of Building Joint Systems
|
1998 |
|
|
|
USDA Bulletin 1751F- 630 630(Rural Utilities service)
|
|
Design of Aria Plant
|
January
1996 |
|
|
|
USDA Bulletin 1751F- 635
(Ural Utilities Service)
|
|
Construction of Aerial Plant
|
June 1996 |
|
|
|
USDA Bulletin 1751F- 642
Rua Utilities Service
|
|
Construction Route Planning of Buried Plant
|
June 1995 |
|
|
|
USDA Bulletin 1751F- 643 Rual Utilities Service
|
|
Underground Conduit and Manhole Design and Construction
|
May 1998 |
|
|
|
USDA Bulletin 1751F- 650 (RualUtilities Service)
|
|
Aerial Plant Guying and Anchoring
|
July 1996
|
|
|
|
USDA Bulletin 1751F- 815 (RualUtilities Service)
|
|
Electrical Protection of Outside Plant
|
May 1995
|